Click here for the plans pdf included of the deck above.
Second floor framing plan pdf.
Floor framing plan notes reaction in kips 6 k u n o beam within a box indicates to drop the beam steel elevation an additional 2 for floor finish.
Check back soon for more deck plans.
Figure 1 7 basic components of floor framing.
Figure 10 19 example of a structural floor framing plan for framing plan framing plan framing plan whats people lookup in this blog.
Although cold formed steel framing for floor systems also is permitted by the irc it is not covered here.
69 chapter 4 floor construction woodframe floor systems and concrete slab on grade floors are discussed in this chapter.
This module also provides.
Second floor framing plan pdf.
Floor joists 23 bridging 29 built up subfloor other29 floor framing at wall projections 31 page chapter 6 wall framing 31 requirements 31 platform construction 31 balloon construction 33 window and door framing 34 end wall framing 36 interior walls 38 lath nailers 39 chapter 7 ceiling and roof framing 40 ceiling joists 40.
Wood frame houses may also be constructed over a crawl space with floor framing similar to that used over a base ment or on a concrete slab as shown in the section on foundations.
When these are assembled learning objective.
State code 6th ed.
Floors of the second story are gener ally supported on load bearing walls in the first story.
3 second gust fastest mile reference wind pressures zone.
Such methods use a 4 foot design module which governs a 16 inch spacing of joists studs rafters and panel sheathing products.
Also check out our gallery of 68 deck designs for inspiration.
Floor framing floor framing consists specifically of the posts girders joists and subfloor.
Second floor framing exterior wall.
12 x 16 flat deck on the ground like a patio our second deck plan is a 12 x 16 wooden deck that is flat on the ground.
Deck exterior and interior load bearing walls beams girders posts and floor framing.
Upon completing as in figure 1 7 they form a level anchored.
Basic modular plan for layout and attachment of framing members.
Above figure 1609 basic wind speed 3 second gust 33 feet above ground exposure c ibc 2003 zone v 30 mph 1 2 3 70 80 90 western mass central mass eastern mass table 1611 3 wind velocity fastest mile 30 feet above the ground exposure c mass.
By frame or masonry walls when the basement area is divided into rooms.
All floor beams are a992 grade 50 steel fy 50 ksi u n o thus.
Rather the reader is referred to the aisi standard for cold formed steel framing prescriptive method for one and two family dwellings aisi 2001 for guidance.
K number of shear studs beam size c camber k at all openings provide a bent plate 1 4 thick high.
Framing must transfer all gravity uplift and lateral loads to the foundation.
It s much like a patio but built as a deck.